SW
2009-04-29 16:18:57 UTC
I'm trying to create an ADTA08 V2.4 Message but when i repeat
PID_11_PatientAddress I get errors.
In the ADT_A08_24_GLO_DEF.xsd this record is set to unbounded maximum
occurence. Anybody had any idea
what i am doing wrong ?
These are the errors :
Error happened in body during serialization
Error # 1
Segment Id: PID_PatientIdentification
Sequence Number: 1
Field Number: 11
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: The node cannot repeat but repetition delimiter
was found
Alternate Encoding System: HL7-BTA
Error # 2
Segment Id: PID_PatientIdentification
Sequence Number: 1
Field Number: 11
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: The node cannot repeat but repetition delimiter
was found
Alternate Encoding System: HL7-BTA
Error # 3
Segment Id: PID_PatientIdentification
Sequence Number: 1
Field Number: 11
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: The node cannot repeat but repetition delimiter
was found
Alternate Encoding System: HL7-BTA
Error # 4
Segment Id: PID_PatientIdentification
Sequence Number: 1
Field Number: 11
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: The node cannot repeat but repetition delimiter
was found
Alternate Encoding System: HL7-BTA
PID_11_PatientAddress I get errors.
In the ADT_A08_24_GLO_DEF.xsd this record is set to unbounded maximum
occurence. Anybody had any idea
what i am doing wrong ?
These are the errors :
Error happened in body during serialization
Error # 1
Segment Id: PID_PatientIdentification
Sequence Number: 1
Field Number: 11
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: The node cannot repeat but repetition delimiter
was found
Alternate Encoding System: HL7-BTA
Error # 2
Segment Id: PID_PatientIdentification
Sequence Number: 1
Field Number: 11
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: The node cannot repeat but repetition delimiter
was found
Alternate Encoding System: HL7-BTA
Error # 3
Segment Id: PID_PatientIdentification
Sequence Number: 1
Field Number: 11
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: The node cannot repeat but repetition delimiter
was found
Alternate Encoding System: HL7-BTA
Error # 4
Segment Id: PID_PatientIdentification
Sequence Number: 1
Field Number: 11
Error Number: 207
Error Description: Application internal error
Encoding System: HL7nnnn
Alternate Error Number: Z100
Alternate Error Description: The node cannot repeat but repetition delimiter
was found
Alternate Encoding System: HL7-BTA